Applicable Standards: United 122 Unicolour Cement Base grout, when mixed with water:
ANSI A118.6; ISO 13007 – 4(CG1) / EN 13888
ANSI Data
Property / Test Method |
Requirement |
Typical Values |
Linear Shrinkage after 27 days: ANSI A118.6: Clause 4.3 |
Max 0.30% |
0.19% - 0.23% |
Water Absorption after 27 days: ANSI A118.6: Clause 4.4 |
Max 18% |
13% - 16% |
Compressive Strength after 1 day: ANSI A118.6: Clause 4.5 |
Min 500 psi (3.43 Mpa) |
520 – 870 psi (3.57 – 5.98 Mpa) |
Compressive Strength after 28 days: ANSI A118.6: Clause 4.5 |
Min 3000 psi (20.62 Mpa) |
3050 – 3200 psi (20.97 – 22.00 Mpa) |
Tensile Strength after 28 days: ANSI A118.6: Clause 4.6 |
Min 250 psi (1.71 Mpa) |
270 – 400 psi (1.85 – 2.75 Mpa) |
Flexural Strength after 28 days: ANSI A118.6: Clause 4.7 |
Min 500 psi (3.43 Mpa) |
550 – 600 psi (3.78 – 4.12 Mpa) |
The grout mortar conforms to ANSI A 118.6
ISO / EN Data
Property / Test Method |
Requirement |
Typical Values |
Abrasion resistance: ISO 13007 – 4: Clause 4.4; EN 12808 - 2 |
2000 mm3 |
1350 – 1700 mm3 |
Flexural strength under standard conditions: ISO 13007 – 4: Clause 4.1.3; EN 12808 - 3 |
2.5 N / mm2 |
3.5 – 3.9 N / mm2 |
Flexural strength under freeze and thaw cycles: ISO 13007 – 4: Clause 4.1.5; EN 12808 - 3 |
2.5 N / mm2 |
3.5 – 3.9 N / mm2 |
² Compressive Strength under standard conditions: ISO 13007 – 4: Clause |
15 N / mm2 |
21 – 22 N / mm2 |
4.1.4; EN 12808- 4 |
- |
- |
4 Compressive Strength under freeze & thaw cycles: ISO 13007 – 4: Clause 4.1.5; EN 12808 - 4 |
15 N / mm2 |
20 – 22 N / mm2 |
Shrinkage: ISO 13007 – 4: Clause 4.3 : EN 12808 - 4 |
< 3mm / m |
1.9 – 2.3 mm/ m |
Water Absorption after 30 Minutes: ISO 13007 – 4: Clause 4.2; EN 12808 - 5 |
5.0 g |
2.5 – 3.0 g |
Water Absorption after 240 Minutes: ISO 13007 – 4: Clause 4.2; EN 12808 - 5 |
10 g |
4.0 –0.8 g |
The grout mortar conforms to ISO 13007 – 4 (CG1) / EN 13888
United 122 Unicolour Cement Base grout, when mixed with United 411 ADMIX
ANSI A118.6; ISO 13007 – 4(CG1) / EN 13888
ANSI Data
Property / Test Method |
Requirement |
Typical Values |
Linear Shrinkage after 27 days: ANSI A118.6: Clause 4.3 |
Max 0.30% |
0.19% - 0.23% |
Water Absorption after 27 days: ANSI A118.6: Clause 4.4 |
Max 18% |
10% - 13% |
Compressive Strength after 1 day: ANSI A118.6: Clause 4.5 |
Min 500 psi (3.43 Mpa) |
570 – 900 psi (3.91 – 6.18 Mpa) |
Compressive Strength after 28 days: ANSI A118.6: Clause 4.5 |
Min 3000 psi (20.62 Mpa) |
3100 – 3200 psi (21.31 – 22.00 Mpa) |
Tensile Strength after 28 days: ANSI A118.6: Clause 4.6 |
Min 250 psi (1.71 Mpa) |
350 – 400 psi (2.40 – 2.75 Mpa) |
Flexural Strength after 28 days: ANSI A118.6: Clause 4.7 |
Min 500 psi (3.43 Mpa) |
600 – 800 psi (4.12 – 5.50 Mpa) |
ISO / EN Data
Property / Test Method |
Requirement |
Typical Values |
Abrasion resistance: ISO 13007 – 4: Clause 4.4; EN 12808 - 2 |
2000 mm3 |
1000 – 1500 mm3 |
Flexural strength under standard conditions: ISO 13007 – 4: Clause 4.1.3; EN 12808 - 3 |
2.5 N / mm2 |
4.0 – 5.5 N / mm2 |
Flexural strength under freeze and thaw cycles: ISO 13007 – 4: Clause 4.1.5; EN 12808 – 3 |
2.5 N / mm2 |
3.5 – 5.0 N / mm2 |
Compressive Strength under standard conditions: ISO 13007 – 4: Clause 4.1.4; EN 12808 – 4 |
1 5 N / mm2 |
21 – 22 N / mm2 |
Compressive Strength under freeze & thaw cycles: ISO 13007 – 4: Clause 4.1.5; EN 12808 - 4 |
4 1 5 N / mm2
|
20 – 22 N / mm2 |
Shrinkage: ISO 13007 – 4: Clause 4.3 : EN 12808 - 4 |
< 3mm / m |
1.9 – 2.3 mm / m |
Water Absorption after 30 Minutes: ISO 13007 – 4: Clause 4.2; EN 12808 - 5 |
5.0 g |
2.0 – 2.5 g |
Water Absorption after 240 Minutes: ISO 13007 – 4: Clause 4.2; EN 12808 - 5 |
10 g |
4.0 – 6.0 g |
The grout mortar conforms to ISO 13007 – 4 (CG1) /EN 13888
Packaging:
✔ 1 Kg, 10 Kg & 20 Kg
Colour:
Choose from range of colours available. Please refer the grout colour chart for choosing the colour required.
Coverage:
Please refer the coverage chart as it depends on the tile size, joint width and depth.
Working Properties at 70° F (21° C)
Working Properties:
Pot life |
60 minutes |
Foot traffic |
24 hours |
Heavy traffic |
72 hours |
Important site Checks: Notes to the specifiers:
✔ It is recommended to check the colour of the grout, if it is meeting the desired colour of the client.
✔ It is recommended to do a small area with actual tile/stone at site and check for any colour ingress into the tile/stone. Many tiles / stones have high absorption which may lead to wet patches /discoloration / colour marks.
✔ Plan to provide proper movement joints, peripheral joints as per TCA, EJ 171 detail to
accommodate movements in tile/stone and use flexible grout / sealant to fill these movement
joints.
✔ When water is used for mixing with grout powder, non-absorbent tiles will have lesser demand of water to be mixed. It is estimated in the range of 3.30 Litres to 3.70 Litres for 10 Kg grout powder.
✔ For better color retention, flexibility and water resistance, use United 411 Grout admix completely replacing water.
Surface Preparation:
✔ Before starting to grout, remove debris in grout joints and lightly sponge the tile surface to remove dust and dirt. Do not clean tiles with acid cleaners. In case acid cleaners were used to clean the tiles, ensure to wash the area with plenty of water to effectively remove acidic particle remains from the joints before commencing grouting. Substrate temperature must between 60°F (16°C) and
90°F (32°C).
Mixing
United 411 ADMIX
Use approximately 3.75 liters of water with powder.Place water in a clean mixing container and add grout powder slowly. Mix by hand or with a slow speed mixer to a smooth stiff consistency. Potable grade of Water should be used for mixing with grout powder for best results.